E–L
Find reference information on document elements of the Microbial Assays for Antibiotics Package, letters E to L.
Edit mode
Select the Edit mode.
The following options are available:
- Select: Allows you to select an existing document.
- Create: Allows you both to select an existing document and to create a new document.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 0...1 | required | none |
Context:
/Combination of microbial assays/Potency data/Column: Document reference/
Equipment
This section allows you to document the equipment used to perform this assay.
Expand the node to add or view information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 0...unbounded | optional | none |
Context:
/Combination of microbial assays/Documentation/
/Cylinder-plate assay (JP 4.02)/Documentation/
/Cylinder-plate assay (USP <81>)/Documentation/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/
Equipment name
Enter the name of the equipment.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 1...1 | required | none |
Context:
/Combination of microbial assays/Documentation/Equipment/choice/
/Cylinder-plate assay (JP 4.02)/Documentation/Equipment/choice/
/Cylinder-plate assay (USP <81>)/Documentation/Equipment/choice/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Equipment/choice/
Equipment reference
Select an equipment document.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 1...1 | required | none |
Context:
/Combination of microbial assays/Documentation/Equipment/choice/
/Cylinder-plate assay (JP 4.02)/Documentation/Equipment/choice/
/Cylinder-plate assay (USP <81>)/Documentation/Equipment/choice/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Equipment/choice/
Exclude from analysis / invalid assay element
Select the 'yes' option from the drop-down list to exclude this assay element from analysis. Or select 'no' to include it.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 1...1 | required | none |
Context:
/Cylinder-plate assay (USP <81>)/Setup/Assay elements/Test/
/Cylinder-plate assay (USP <81>)/Setup/Assay elements/Control/
/Turbidimetric assay (USP <81>, JP 4.02)/Setup/Assay elements/Test/
/Turbidimetric assay (USP <81>, JP 4.02)/Setup/Assay elements/Control/
File name
Automatically inserts the file name of the data source when you import data.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 0...1 | optional | none |
Context:
/Combination of microbial assays/Documentation/Data source/
/Cylinder-plate assay (JP 4.02)/Documentation/Data source/
/Cylinder-plate assay (USP <81>)/Documentation/Data source/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Data source/
Folder key
Select a folder to require referenced documents be elements of this folder.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 0...1 | optional | none |
Context:
/Combination of microbial assays/Potency data/Column: Document reference/
Generator key
Enter a document key to require referenced documents be generated by a document that matches the key.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 0...1 | optional | none |
Context:
/Combination of microbial assays/Potency data/Column: Document reference/
Import comment
Enter text to provide additional information on the data import.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:string | 0...1 | optional | none |
Context:
/Combination of microbial assays/Documentation/Data source/
/Cylinder-plate assay (JP 4.02)/Documentation/Data source/
/Cylinder-plate assay (USP <81>)/Documentation/Data source/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Data source/
Import module identification
Automatically inserts information that allows you to identify the import module used to import data.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 0...1 | optional | none |
Context:
/Combination of microbial assays/Documentation/Data source/
/Cylinder-plate assay (JP 4.02)/Documentation/Data source/
/Cylinder-plate assay (USP <81>)/Documentation/Data source/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Data source/
Import time stamp
Automatically inserts the current date and time when you import data.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:dateTime | 0...1 | optional | none |
Context:
/Combination of microbial assays/Documentation/Data source/
/Cylinder-plate assay (JP 4.02)/Documentation/Data source/
/Cylinder-plate assay (USP <81>)/Documentation/Data source/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Data source/
Incubation
This documentation section allows you to provide information on the final incubation of the completed cylinder plates or tube rack. Expand the node to add or view information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 0...1 | optional | none |
Context:
/Cylinder-plate assay (JP 4.02)/Documentation/
/Cylinder-plate assay (USP <81>)/Documentation/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/
Incubation
This section allows you to provide information on the incubation during preparation of the test organism inoculum. Expand the node to add or view information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 0...1 | optional | none |
Context:
/Cylinder-plate assay (JP 4.02)/Documentation/Inoculum/Test organism/
/Cylinder-plate assay (USP <81>)/Documentation/Inoculum/Test organism/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Inoculum/Test organism/
Incubation medium
This section allows you to provide information on the ingredients of the incubation medium and its pH value. Expand the node to add or view information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 1...1 | required | none |
Context:
/Cylinder-plate assay (JP 4.02)/Documentation/Inoculum/Test organism/Incubation/
/Cylinder-plate assay (USP <81>)/Documentation/Inoculum/Test organism/Incubation/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Inoculum/Test organism/Incubation/
Ingredient
This section allows you to document the name and amount of an ingredient used for the base layer medium. Expand the node to add or view information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 1...unbounded | required | none |
Context:
/Cylinder-plate assay (JP 4.02)/Documentation/Base layer/Medium/
/Cylinder-plate assay (USP <81>)/Documentation/Base layer/Medium/
Ingredient
This section allows you to document the name and amount of an ingredient used for the inoculum medium. Expand the node to add or view information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 1...unbounded | required | none |
Context:
/Cylinder-plate assay (USP <81>)/Documentation/Inoculum/Inoculum medium/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Inoculum/Inoculum medium/
Ingredient
This section allows you to document the name and amount of an ingredient used for the incubation medium. Expand the node to add or view information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 1...unbounded | required | none |
Context:
/Cylinder-plate assay (JP 4.02)/Documentation/Inoculum/Test organism/Incubation/Incubation medium/
/Cylinder-plate assay (USP <81>)/Documentation/Inoculum/Test organism/Incubation/Incubation medium/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Inoculum/Test organism/Incubation/Incubation medium/
Ingredient
This section allows you to document the name and amount of an ingredient used for the seed layer medium. Expand the node to add or view information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 1...unbounded | required | none |
Context:
/Cylinder-plate assay (JP 4.02)/Documentation/Inoculum/Seed layer/Medium/
Ingredient amount
Enter the amount of the ingredient used for this medium.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 1...1 | required | none |
Context:
/Cylinder-plate assay (JP 4.02)/Documentation/Inoculum/Test organism/Incubation/Incubation medium/Ingredient/
/Cylinder-plate assay (JP 4.02)/Documentation/Inoculum/Seed layer/Medium/Ingredient/
/Cylinder-plate assay (JP 4.02)/Documentation/Base layer/Medium/Ingredient/
/Cylinder-plate assay (USP <81>)/Documentation/Inoculum/Test organism/Incubation/Incubation medium/Ingredient/
/Cylinder-plate assay (USP <81>)/Documentation/Inoculum/Inoculum medium/Ingredient/
/Cylinder-plate assay (USP <81>)/Documentation/Base layer/Medium/Ingredient/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Inoculum/Test organism/Incubation/Incubation medium/Ingredient/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Inoculum/Inoculum medium/Ingredient/
Ingredient name
Enter the name of the ingredient.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 1...1 | required | none |
Context:
/Cylinder-plate assay (JP 4.02)/Documentation/Inoculum/Test organism/Incubation/Incubation medium/Ingredient/
/Cylinder-plate assay (JP 4.02)/Documentation/Inoculum/Seed layer/Medium/Ingredient/
/Cylinder-plate assay (JP 4.02)/Documentation/Base layer/Medium/Ingredient/
/Cylinder-plate assay (USP <81>)/Documentation/Inoculum/Test organism/Incubation/Incubation medium/Ingredient/
/Cylinder-plate assay (USP <81>)/Documentation/Inoculum/Inoculum medium/Ingredient/
/Cylinder-plate assay (USP <81>)/Documentation/Base layer/Medium/Ingredient/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Inoculum/Test organism/Incubation/Incubation medium/Ingredient/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Inoculum/Inoculum medium/Ingredient/
Inoculum
This documentation section allows you to provide detailed information on the inoculum. Expand the node to add or view information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 0...1 | optional | none |
Context:
/Cylinder-plate assay (JP 4.02)/Documentation/
Inoculum
This documentation section allows you to provide detailed information on the inoculum. Expand the node to add or view information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 0...1 | optional | none |
Context:
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/
Inoculum
This documentation section allows you to provide detailed information on the inoculum. Expand the node to add or view information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 0...1 | optional | none |
Context:
/Cylinder-plate assay (USP <81>)/Documentation/
Inoculum concentration
Enter the concentration of the inoculum.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 1...1 | required | none |
Context:
/Cylinder-plate assay (USP <81>)/Documentation/Inoculum/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Inoculum/
Inoculum medium
This section allows you to provide information on the ingredients of the inoculum medium and its pH value. Expand the node to add or view information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 0...1 | optional | none |
Context:
/Cylinder-plate assay (USP <81>)/Documentation/Inoculum/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Inoculum/
Inoculum vol%
Enter the vol% of the inoculum.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 1...1 | required | none |
Context:
/Cylinder-plate assay (JP 4.02)/Documentation/Inoculum/
Inoculum volume per plate
Enter the volume of inoculum to be used per plate.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 1...1 | required | none |
Context:
/Cylinder-plate assay (USP <81>)/Documentation/Inoculum/
Inoculum volume per tube
Enter the volume of inoculum to be used per tube.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 1...1 | required | none |
Context:
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/Inoculum/
Key
Enter a key to identify the user variable.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 1...1 | required | none |
Context:
/Combination of microbial assays/Documentation/User variable/
/Cylinder-plate assay (JP 4.02)/Documentation/User variable/
/Cylinder-plate assay (USP <81>)/Documentation/User variable/
/Turbidimetric assay (USP <81>, JP 4.02)/Documentation/User variable/
Linked document
Select a document.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 0...unbounded | optional | none |
Context:
/Combination of microbial assays/Comment/
/Cylinder-plate assay (JP 4.02)/Comment/
/Cylinder-plate assay (USP <81>)/Comment/
/Turbidimetric assay (USP <81>, JP 4.02)/Comment/
Logarithm base
Select the logarithm to be used for transforming your dose values.
The following options are available from the drop-down list:
- Binary logarithm (base 2)
- Natural logarithm (base e)
- Decimal logarithm (base 10)
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 1...1 | required | none |
Context:
/Cylinder-plate assay (USP <81>)/Analysis/choice/Logarithmic dose transformation/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/choice/Logarithmic dose transformation/
Logarithm base
Select the logarithm to be used for transforming potency values during combination.
The following options are available from the drop-down list:
- Binary logarithm (base 2)
- Natural logarithm (base e)
- Decimal logarithm (base 10)
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 1...1 | required | none |
Context:
/Combination of microbial assays/Analysis/
Logarithm base
Select the logarithm to be used for transforming your response values.
The following options are available from the drop-down list:
- Binary logarithm (base 2)
- Natural logarithm (base e)
- Decimal logarithm (base 10)
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:token | 1...1 | required | none |
Context:
/Cylinder-plate assay (USP <81>)/Analysis/Response data processing/choice/Transformation/choice/Logarithmic response transformation/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Response data processing/choice/Transformation/choice/Logarithmic response transformation/
Logarithmic dose transformation
Performs a logarithmic transformation of the dose values at the beginning of the calculation.
Expand the node to add or view information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 1...1 | required | none |
Context:
/Cylinder-plate assay (USP <81>)/Analysis/choice/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/choice/
Logarithmic response transformation
Select an option from the 'Logarithm base' drop-down list below to specify the logarithm to be used for transforming your response values.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
Node | 1...1 | required | none |
Context:
/Cylinder-plate assay (USP <81>)/Analysis/Response data processing/choice/Transformation/choice/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Response data processing/choice/Transformation/choice/
Lower margin
Enter the Lower margin of the test as decimal number. To pass the test, the observed value must be greater than or equal to the Lower margin.
Please consult the help page of the test for additional information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:double | 0...1 | optional | none |
Context:
/Combination of microbial assays/Analysis/Test system/choice/Test: Combined potency - Value/
/Combination of microbial assays/Analysis/Test system/choice/Test: Half width of confidence interval/
/Combination of microbial assays/Analysis/Test system/choice/Test: Combined potency - Confidence interval/
/Combination of microbial assays/Analysis/Test system/choice/Test: Combined potency - Confidence interval (%)/
/Combination of microbial assays/Analysis/Test system/choice/Test: Combined potency - Range/
/Combination of microbial assays/Analysis/Test system/choice/Test: Combined potency - Range (%)/
/Combination of microbial assays/Analysis/Test system/choice/Test: Potency - CV (%)/
/Combination of microbial assays/Analysis/Test system/choice/Test: Number of valid assays (test state)/
/Combination of microbial assays/Analysis/Test system/choice/Test: Number of potency outliers/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Assay suitability tests/choice/Test: Sample - Mean response/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Assay suitability tests/choice/Test: Correction point/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Assay suitability tests/choice/Test: Parameter/property point estimate/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Assay suitability tests/choice/Test: Potency of the working sample/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Assay suitability tests/choice/Test: Absolute potency/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Assay suitability tests/choice/Test: Relative potency (percentage of reference concentration)/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Sample suitability tests/choice/Test: Sample - Mean response/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Sample suitability tests/choice/Test: Correction point/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Sample suitability tests/choice/Test: Parameter/property point estimate/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Sample suitability tests/choice/Test: Potency of the working sample/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Sample suitability tests/choice/Test: Absolute potency/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Sample suitability tests/choice/Test: Relative potency (percentage of reference concentration)/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Assay suitability tests/choice/Test: Step - Standard deviation/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Assay suitability tests/choice/Test: Step - Relative standard deviation CV (%)/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Assay suitability tests/choice/Test: Correction point - Standard deviation/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Assay suitability tests/choice/Test: Correction point - Relative standard deviation CV (%)/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Assay suitability tests/choice/Test: Plate correction/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Sample suitability tests/choice/Test: Step - Standard deviation/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Sample suitability tests/choice/Test: Step - Relative standard deviation CV (%)/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Sample suitability tests/choice/Test: Correction point - Standard deviation/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Sample suitability tests/choice/Test: Correction point - Relative standard deviation CV (%)/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Sample suitability tests/choice/Test: Plate correction/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Assay suitability tests/choice/Test: Coefficient of determination (R²)/
/Cylinder-plate assay (USP <81>)/Analysis/Test system/Sample suitability tests/choice/Test: Coefficient of determination (R²)/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Response range/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Parameter/property point estimate/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Potency of the working sample/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Absolute potency/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Relative potency (percentage of reference concentration)/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Response range/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Parameter/property point estimate/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Potency of the working sample/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Absolute potency/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Relative potency (percentage of reference concentration)/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Step - Standard deviation/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Step - Relative standard deviation CV (%)/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Combined standard deviation of the standard/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Step - Standard deviation/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Step - Relative standard deviation CV (%)/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Combined standard deviation of the standard/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Coefficient of determination (R²)/
/Turbidimetric assay (USP <81>, JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Coefficient of determination (R²)/
Lower margin
Enter the Lower margin of the test as a decimal number that is greater than or equal to zero. To pass the test, the observed value must be greater than or equal to the Lower margin.
Please consult the help page of the test for additional information.
This element has the following attributes:
Data type | Multiplicity | Usage | Default value |
xs:double | 0...1 | optional | none |
Context:
/Cylinder-plate assay (JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Potency of the working sample/
/Cylinder-plate assay (JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Absolute potency/
/Cylinder-plate assay (JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Potency factor A/
/Cylinder-plate assay (JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Sample mean response/
/Cylinder-plate assay (JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Sample response sum/
/Cylinder-plate assay (JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Sample response standard deviation/
/Cylinder-plate assay (JP 4.02)/Analysis/Test system/Assay suitability tests/choice/Test: Sample relative response standard deviation/
/Cylinder-plate assay (JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Potency of the working sample/
/Cylinder-plate assay (JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Absolute potency/
/Cylinder-plate assay (JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Potency factor A/
/Cylinder-plate assay (JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Sample mean response/
/Cylinder-plate assay (JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Sample response sum/
/Cylinder-plate assay (JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Sample response standard deviation/
/Cylinder-plate assay (JP 4.02)/Analysis/Test system/Sample suitability tests/choice/Test: Sample relative response standard deviation/